Your selection
SCG PCI unfaced · 25 mm
- Thickness (mm)
- 25
- Density (kg/m³)
- 64
- Length (mm)
- 1000
- Pipe size
- NPS 1/2" – 18"
- Iron pipe size (inch)
Factory wholesale prices, no minimum order · tell us the quantity to get a price
Sound coming in or going out (sound insulation)
Echoey rooms (sound absorption)

Pre-formed glass-wool section for steel pipes — hot, cold and exposed piping operating at 10–540 °C.
Iron pipes are named by a nominal size in inches, not the measured size: a 1/2 in pipe measures about 21 mm across the outside.
3. Pipe diameter
Choose the pipe size first; it is shown here.
No size chosen yet
Answer every step above to ask about that exact item, or ask without choosing.
Ask about this productYour selection
Factory wholesale prices, no minimum order · tell us the quantity to get a price
Your selection
Factory wholesale prices, no minimum order · tell us the quantity to get a price
Your selection
Factory wholesale prices, no minimum order · tell us the quantity to get a price
Your selection
Factory wholesale prices, no minimum order · tell us the quantity to get a price
Your selection
Factory wholesale prices, no minimum order · tell us the quantity to get a price
Your selection
Factory wholesale prices, no minimum order · tell us the quantity to get a price
See all models and sizesManufacturer documentsTechnical specifications
Pre-formed glass-wool section for iron pipe · PCI unfaced · PCIF aluminium-foil faced
SCG PCI is a pre-formed glass-wool section for steel pipes operating at 10–540 °C, in commercial buildings, factories, offices, department stores, hospitals, hotels and homes. Density 64 kg/m³; 25, 38 and 50 mm thick; 1 m long; for 1/2" to 18" pipe.
Glass wool (fibreglass) · Pipe section
Thickness 25–50 mm · 64 kg/m³ — Choose a size
SCG thermal insulation catalogue for air-conditioning and industrial work (pages 13–17: pipe insulation)
Technical data from the manufacturer's documents SCG · Checked 26 Sept 2026
All values come from the manufacturer's documents, with conditions and test standards. Values the documents do not state are not shown.
| Property | Value | Conditions / standard | Source |
|---|---|---|---|
| Thermal conductivity (λ) | 0.032 / 0.039 / 0.046 / 0.063 W/m·K | at 24 / 66 / 121 / 204 °C mean (test standard not stated) | SCG thermal insulation catalogue for air-conditioning and industrial work (pages 13–17: pipe insulation), p. 16 |
| Service temperature range | 10 – 540 °C | — | SCG thermal insulation catalogue for air-conditioning and industrial work (pages 13–17: pipe insulation), p. 13 |
| Reaction to fire | FS < 25 · SD < 50 | flame spread / smoke developed · ASTM E84 | SCG thermal insulation catalogue for air-conditioning and industrial work (pages 13–17: pipe insulation), p. 16 |
| Moisture sorption | 0.2% by volume | ASTM C1104 | SCG thermal insulation catalogue for air-conditioning and industrial work (pages 13–17: pipe insulation), p. 16 |
| Model | Thickness (mm) | Density (kg/m³) | Length (mm) | Pipe size |
|---|---|---|---|---|
| PCI | 25 | 64 | 1000 | NPS 1/2" – 18" |
| PCI | 38 | 64 | 1000 | NPS 1/2" – 18" |
| PCI | 50 | 64 | 1000 | NPS 1/2" – 18" |
| PCIF | 25 | 64 | 1000 | NPS 1/2" – 18" |
| PCIF | 38 | 64 | 1000 | NPS 1/2" – 18" |
| PCIF | 50 | 64 | 1000 | NPS 1/2" – 18" |
Pack quantities and prices — ask us on LINE
Send the area details or site photos — we'll suggest the model and quantity
Ask via LINECheck the message below, then press “Open LINE”: LINE opens with this message. If LINE does not open, copy the message into the chat, or call us.
Scan to add LINE @x2525
On a computer: press “Copy message”, scan the QR code with your phone to add LINE @x2525, then paste the message in the chat. Or just call us.
3 steps to reach us
Works when the LINE app is installed on this computer
Or reach us another way
Call us in opening hours, Monday to Saturday 8:00–17:00 · or add us on LINE and just type