Your selection
ROCKWOOL Conlit H110 110 kg/m³ · 25 mm · 0.6 × 1.2 m
- Thickness (mm)
- 25
- Density (kg/m³)
- 110
- Width (mm)
- 600
- Length (mm)
- 1200
Sound coming in or going out (sound insulation)
Echoey rooms (sound absorption)

Specially formulated ROCKWOOL stone wool made to withstand high temperatures in a fire, used as part of passive fire-protection systems.
No size chosen yet
Answer every step above to ask about that exact item, or ask without choosing.
Ask about this productYour selection
Your selection
Your selection
Your selection
See all models and sizesManufacturer documentsTechnical specifications
Specially formulated stone wool for fire-protection systems · 110 kg/m³
Conlit is a specially formulated ROCKWOOL stone wool made to withstand high temperatures in a fire, used as part of passive fire-protection systems. Conlit H is designed to resist fire exposure for longer with minimal shrinkage and has been used by fire-door makers in fire-resistance testing. Conlit H110 comes in 25, 50, 75 and 100 mm, 600 × 1,200 mm.
Stone wool (rock wool) · Slab
Thickness 25–100 mm · 110 kg/m³ — Choose a size
Fire-resistance ratings belong to tested systems, not to the slab. Install to the system and obtain local-authority approvals as the maker states.
Conlit data sheet 300 319-07/22 V3 (H110 / C160)
Technical data from the manufacturer's documents ROCKWOOL · Checked 26 Sept 2026
All values come from the manufacturer's documents, with conditions and test standards. Values the documents do not state are not shown.
| Property | Value | Conditions / standard | Source |
|---|---|---|---|
| Thermal conductivity (λ) | 0.039 W/m·K | at 20 °C · ASTM C177 / C518 | Conlit data sheet 300 319-07/22 V3 (H110 / C160), p. 2 |
| Density | 110 kg/m³ | — | Conlit data sheet 300 319-07/22 V3 (H110 / C160), p. 2 |
| Water absorption (partial immersion) | < 0.5 kg/m² | EN 1609:97 | Conlit data sheet 300 319-07/22 V3 (H110 / C160), p. 2 |
| Reaction to fire | ROCKWOOL stone wool is non-combustible, melting point approx. 1,000 °C | general statement in the data sheet | Conlit data sheet 300 319-07/22 V3 (H110 / C160), p. 1 |
Sound insulation ratings (STC / Rw) and fire-resistance ratings belong to the complete tested wall, ceiling or floor system — not to the insulation on its own.
| Model | Thickness (mm) | Density (kg/m³) | Width (mm) | Length (mm) |
|---|---|---|---|---|
| H110 | 25 | 110 | 600 | 1200 |
| H110 | 50 | 110 | 600 | 1200 |
| H110 | 75 | 110 | 600 | 1200 |
| H110 | 100 | 110 | 600 | 1200 |
Pack quantities and prices — ask us on LINE
Send the area details or site photos — we'll suggest the model and quantity
Ask via LINECheck the message below, then press “Open LINE”. On a phone LINE opens with this message; on a computer LINE shows a QR code to scan with your phone. If LINE does not open, copy the message into the chat, or call us.
Add us on LINE: @x2525 · Call 062-195-1909