ROCKWOOL stone wool slabs for insulating equipment walls, boilers, columns, tanks and hot ducts in industry, in six grades by density and service temperature.
Stone wool slabs for high-temperature work · 6 grades, 60–160 kg/m³
Thickness
25–100 mm
Density
60–160 kg/m³
Maximum service temperature
450–850 °C ASTM C411 / C447
Thermal conductivity (λ)
0.038–0.039 W/m·K at 50 °C mean · ASTM C177
What is it?
ProRox SL is a stone wool slab range for industrial thermal insulation on flat surfaces such as equipment walls, boilers, columns and tanks. Grades: SL 930 SA (60 kg/m³, up to 450 °C), SL 950 SA (80), SL 960 SA (100), SL 970 SA (128) and SL 540 SA (160), rated up to 650 °C, and SL 978 SA (110 kg/m³), rated up to 850 °C, according to ROCKWOOL Thailand data sheets.
What is it made of?
Stone wool (rock wool) · Facing: Unfaced (SL 930 SA: one-side aluminium foil or glass tissue facing on request) · Slab
Values here are material properties from the manufacturer's documents. The thickness you need depends on the surface temperature, the target outer-surface temperature and the cladding — have it calculated by the designer.
Where does the data come from?
ProRox SL 950 SA — 200 351TH-08/25 V3 (EN) · ProRox SL 930 SA — 200 349TH-08/25 V3 (EN)
Technical data from the manufacturer's documents ROCKWOOL · Checked 13 Oct 2026
Technical specifications
Technical values for each model from the manufacturer's data sheet. They apply to every thickness of that model unless a condition is given.
SL 930 SA
Density
60 kg/m³
Maximum service temperature
450 °C
Densitynominal density
60 kg/m³
Thermal conductivity (λ)at 50 °C mean
0.039 W/m·K
Thermal conductivity (λ) at 100 °Cat 100 °C mean
0.047 W/m·K
Thermal conductivity (λ) at 150 °Cat 150 °C mean
0.054 W/m·K
Thermal conductivity (λ) at 200 °Cat 200 °C mean
0.064 W/m·K
Thermal conductivity (λ) at 250 °Cat 250 °C mean
0.075 W/m·K
SL 950 SA
Density
80 kg/m³
Maximum service temperature
650 °C
Densitynominal density
80 kg/m³
Thermal conductivity (λ)at 50 °C mean
0.038 W/m·K
Thermal conductivity (λ) at 100 °Cat 100 °C mean
0.046 W/m·K
Thermal conductivity (λ) at 150 °Cat 150 °C mean
0.053 W/m·K
Thermal conductivity (λ) at 200 °Cat 200 °C mean
0.062 W/m·K
Thermal conductivity (λ) at 250 °Cat 250 °C mean
0.072 W/m·K
Thermal conductivity (λ) at 300 °Cat 300 °C mean
0.081 W/m·K
SL 960 SA
Density
100 kg/m³
Maximum service temperature
650 °C
Densitynominal density
100 kg/m³
Thermal conductivity (λ)at 50 °C mean
0.038 W/m·K
Thermal conductivity (λ) at 100 °Cat 100 °C mean
0.044 W/m·K
Thermal conductivity (λ) at 150 °Cat 150 °C mean
0.050 W/m·K
Thermal conductivity (λ) at 200 °Cat 200 °C mean
0.057 W/m·K
Thermal conductivity (λ) at 250 °Cat 250 °C mean
0.065 W/m·K
Thermal conductivity (λ) at 300 °Cat 300 °C mean
0.075 W/m·K
SL 978 SA
Density
110 kg/m³
Maximum service temperature
850 °C
Densitynominal density
110 kg/m³
Thermal conductivity (λ)at 50 °C mean
0.038 W/m·K
Thermal conductivity (λ) at 100 °Cat 100 °C mean
0.045 W/m·K
Thermal conductivity (λ) at 150 °Cat 150 °C mean
0.053 W/m·K
Thermal conductivity (λ) at 200 °Cat 200 °C mean
0.061 W/m·K
Thermal conductivity (λ) at 250 °Cat 250 °C mean
0.072 W/m·K
Thermal conductivity (λ) at 300 °Cat 300 °C mean
0.083 W/m·K
SL 970 SA
Density
128 kg/m³
Maximum service temperature
650 °C
Densitynominal density
128 kg/m³
Thermal conductivity (λ)at 50 °C mean
0.038 W/m·K
Thermal conductivity (λ) at 100 °Cat 100 °C mean
0.043 W/m·K
Thermal conductivity (λ) at 150 °Cat 150 °C mean
0.049 W/m·K
Thermal conductivity (λ) at 200 °Cat 200 °C mean
0.056 W/m·K
Thermal conductivity (λ) at 250 °Cat 250 °C mean
0.064 W/m·K
Thermal conductivity (λ) at 300 °Cat 300 °C mean
0.074 W/m·K
SL 540 SA
Density
160 kg/m³
Maximum service temperature
650 °C
Densitynominal density
160 kg/m³
Thermal conductivity (λ)at 50 °C mean
0.038 W/m·K
Thermal conductivity (λ) at 100 °Cat 100 °C mean
0.045 W/m·K
Thermal conductivity (λ) at 150 °Cat 150 °C mean
0.052 W/m·K
Thermal conductivity (λ) at 200 °Cat 200 °C mean
0.062 W/m·K
Thermal conductivity (λ) at 250 °Cat 250 °C mean
0.070 W/m·K
Thermal conductivity (λ) at 300 °Cat 300 °C mean
0.079 W/m·K
All models
Reaction to fire
Euroclass A1 · ASTM E84 passed (flame spread / smoke development) all models (same in each model's data sheet)